Low Vacuum Dehydration Machine (PLC Operated Unit)

Low Vacuum Dehydration Machine (PLC Operated Unit)

At Kleenoil through our manufacturing expertise and experience in the field of lubricants, Kleenoil has developed an all-new LVDH (Low Vacuum Dehydration Machine) to remove water from the oil.

With the Low Vacuum Dehydration Machine LVDH being the most cost-friendly and reliable way to remove contaminants from hydraulic oil, the machine is most suitable in situations where large amounts of water get emulsified into the oil.

The Low Vacuum Dehydration Machine LVDH uses an extensive process to remove water and gas from oil at temperatures lower than 53o C, it significantly reduces oxidation during the dehydration process. A low Vacuum Dehydration Machine LVDH is fast, inexpensive, and an automated system.

Generally, water as a contaminant exists in three phases in hydraulic systems. LVDH Failure to remove water in any of these states can be catastrophic to the entire system.

At any given point, it is important to choose a machine that can remove water in all three phases.

PRINCIPLES OF OPERATION:

Contaminated oil is drawn into the Kleenoil Low Vacuum Dehydration machine by a vacuum of 700 millibars. The oil passes through the in-line low-watt density heater where the oil is heated to an optimum temperature of 66°C-70°C (depending on oil flash point capacity). The oil then enters the distillation column where it is exposed to the vacuum using special dispersal elements.
This increases the exposed surface area of the oil and converts the water to vapour form, which is then drawn through the condenser by the vacuum pump. The water-free oil falls to the bottom of the column and is removed by a heavy-duty lube oil pump. This pump forces the dry oil through a final particulate removal filter. Clean oil passes out of the unit, back to the reservoir – and into the system.

Effects of Water Contamination:

Water is one of the most common contaminants in a fluid system and one of the most damaging. When water contaminates a system, it can cause serious problems such as:

  • Corrosion by etching metal
  • Abrasive wear in hydraulic components
  • Fluid breakdown, reduction of lubricating

ADVANTAGES of the KLEENOIL LVDH PLC:

  • Easy to operate for an efficient method for continuous removal of moisture from oil.
  • No damage to oil and the unit offers dry, dehydrated oil.
  • Significantly reduced residence time with fast and efficient heat transfer
  • Reduced pressure drop
  • Ability to process materials that are sensitive to thermal degradation or prone to
  • fouling and ability to process high-viscosity and high-solid materials
  • High evaporation ratios (> 95%)
  • Easy to clean/maintain equipment
  • Digital Screen for system feedback
  • Optional IOT 4.0 for remote information to the user

  • Removes water and dissolved gases from oil
  • Water reduction below 300 ppm
  • No oil quality damaged since temperature ranges between 45 to 60 deg.
  • Plug and Play
  • Run both offline and online
  • PLC -Operated
Specification Details
Electrical Supply 415v AC, 3 Phase, 50Hz
Control Panel PLC with 7” HMI Display
Oil Inlet/Outlet SAE R1AT 1” BSP hose pipes with end fittings
Discharge Pump Details

Type:

Nominal Flow Rates:

Operating Pressure:

Motor Power:

 

DG- 50 Trochoidal Monoblock

50 Lpm

0-6 Bar (Kg/Sq.Cm.)

2.0 Hp

Vacuum Chamber Capacity 110 Liters
Operating Vacuum Upto 750mm Of Hg @ Msl
Heater Type Low Watt Density Heaters
Heater Load 15 KW 440v AC
Vacuum Pump Details

Capacity:

Drive:

Motor Power:

 

300 Lpm

Direct Driven

1.0 Hp, 2800 Rpm, 3 Phase

Overall Dimensions

Length:

Width:

Height:

 

1790mm

1100mm

1500mm

Weight of the Unit

Empty:

Full:

 

400 Kgs Approx

530 Kgs Approx

Provided With Fixed castor wheel, two swivel with lock
Duty Conditions Continuous
Color Shade Anthracite Grey (Ral 7016)
Water Discharge Auto-drain
Condenser 0.5 TR